Test Code PIK3T PIK3CA Mutation Analysis, Tumor
Necessary Information
A pathology report (final or preliminary), at minimum containing the following information, must accompany specimen for testing to be performed:
1. Patient name
2. Block number-must be on all blocks, slides, and paperwork (can be handwritten on the paperwork)
3. Tissue collection date
4. Source of the tissue
Specimen Required
This assay requires at least 20% tumor nuclei.
The amount of tissue needed is dependent on a variety of preanalytical factors (eg, cellularity, ischemic time, fixation).
The FFPE input required is equivalent to a 4 to 5 micron slide thickness with a total tumor surface area of 100 mm(2). This can be created by combining material from multiple slides from one tissue block.
Preferred:
Specimen Type: Tissue block
Collection Instructions: Submit a formalin-fixed, paraffin-embedded tissue block.
Acceptable:
Specimen Type: Tissue slide
Slides: 1 stained and 10 unstained
Collection Instructions: Submit 1 slide stained with hematoxylin and eosin and 10 unstained, nonbaked slides with 5-micron thick sections of the tumor tissue.
Useful For
Identification of hormone receptor positive and human epidermal growth factor receptor 2 negative (HR+/HER2-) advanced breast cancer tumors that may be eligible for treatment with targeted kinase inhibitor therapy (eg, alpelisib).
Testing Algorithm
When this test is ordered, slide review will always be performed at an additional charge.
Method Name
Polymerase Chain Reaction (PCR)
Reporting Name
PIK3CA Mutation Analysis, TumorSpecimen Type
VariesSpecimen Minimum Volume
See Specimen Required
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Varies | Ambient (preferred) | ||
Refrigerated |
Reject Due To
Specimens that have been decalcified (all methods) Â Specimens that have not been formalin-fixed, paraffin-embedded |
Reject |
Reference Values
An interpretive report will be provided
Day(s) Performed
Monday through Friday
Report Available
8 to 12 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test has been modified from the manufacturer's instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
81309
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
PIK3T | PIK3CA Mutation Analysis, Tumor | 60034-6 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
616654 | Result Summary | 50397-9 |
616655 | Result | 82939-0 |
616656 | Interpretation | 69047-9 |
616657 | Additional Information | 48767-8 |
616658 | Specimen | 31208-2 |
616659 | Source | 31208-2 |
616660 | Tissue ID | 80398-1 |
616661 | Released By | 18771-6 |
Forms
If not ordering electronically, complete, print, and send an Oncology Test Request (T729) with the specimen.